Same as Aggregates, there are some methods of sampling of bitumen for testing in laboratory from various place .but generally there are three source which may take sample for testing. and also the importance of sampling is as high as testing of samples, because if the material taken from source be not uniform ,it will affect the test and final result. below is the three most important method of sampling of bitumen for testing.
Sampling from Storage Tank |
Sampling from Storage Tanks |
|
Step |
|
1 |
Seal inlet valves of the tank prior to sampling, if applicable. |
2 |
Wearing the required safety equipment, open the appropriate drain cock on the tank and allow enough material to flow to ensure that a representative sample may be taken. |
3 |
Fill the sample container from the drain cock. Use a friction-lid can for AC graded materials; a screw top can for cutbacks, emulsions, and other asphalts that are liquid at 25 °C (77 °F). |
4 |
Seal the sample container. |
5 |
Attach identifying tags to the sample container, clearly showing the name of the producer, the grade, the tank and seal numbers, and any other identifying information. |
6 |
Enter all required sample information, including all information from the sample container. |
Please be assure to do:
Be sure to take enough sample from the tank according the below conditions:
Sampling from Pipe line |
When tank cars, distributors, or drums are filled from the pipeline, the sample may be taken directly from the pipeline.
A sampling pipe of not more than 1/8th the diameter of the pipeline, with a drain cock which can be used to regulate the flow through it is required. This pipe must be inserted into a rising section of the line on the discharge side of the pump, with its opening turned to face the flow of the liquid.
Use the following procedure when sampling liquid bituminous materials from pipelines.
Step |
Action |
|
Open
the drain cock, allow enough material to flow into a waste container to
clear the sample cock and sample line of old material. |
|
Fill
the sample container from the drain cock. |
|
Material taken in a receiver throughout the loading process should be
thoroughly mixed and the sample container filled. |
|
Tightly close the sample container. Label the container and enter the information needed. |
Sampling from Tank or Truck |
Just follow the instruction below and consider all notes in tank sampling.
Step | Action |
|
Carefully inspect the
material for the presence of foam, sediment, or free water on top or bottom
of the car or truck. Make notation of such observations. |
|
When sampling from
distributors, mix the material thoroughly with the pump. |
|
When sampling semi-solid
materials, heat the materials to fluidity. (Sample all liquid materials
without heating, if possible.) |
|
Obtain the sample by lowering
a 1 L (1 qt.) can, attached to the sampling device, through the top hatch. |
|
Pour the material into a
clean container. |
|
When sampling from a
distributor, take the sample from the spray bar by placing a can under one
of the nozzles and opening the spray bar valve for that nozzle. |
|
Label the sample container and complete other information needed. |